We specialize in esd worksurface mats esd table top mats esd floor mats esd anti fatigue floor mats esd floor runners esd foam mats and the accessories you would need to set up your assembly line.
Esd floor mat installation.
Once anti static mats are covering the table and floor you are on your way to being in compliance with ansi esd s6 1 esd grounding methods requirements for workstations.
Grounding to an earth ground step 1.
Esd ground cords can be used to ground both table and floor mats.
Drill a hole in the support column.
Esd table floor mats static dissipative mats drain static charge from personnel and feature superior resistance to heat abrasion and chemicals.
Snaps on the corner of the mat allow you to bypass the floor sending static directly from the mat to an electrical outlet using a grounding cable.
Insert the post from underneath and apply the stud over the protruding post on the top side.
Freestyle esd plus download pdf.
Conductive materials are usually used as floor mats which is defined by ansi esd s7 1 as less than 1 x 106 ohms.
When choosing an esd floor factor maintenance and repair into total cost of ownership.
We can custom cut and make special kits for your particular requirements.
Static control is critical during electronic assembly and manufacturing.
The esd ground must be tied directly to and at the same.
Fit the anvil under the post and place the punch inside the stud and hammer the post or use an arbor press until it.
Esd grounding methods kit.
Conductive adhesive eliminates the need for expensive copper equipotential grounding grids of the past.
General grounding guidelines 1.
Punch a 5mm diameter hole at the desired location of the mat.
With a grounding screw or clamp attach the end of the copper strap directly to the column.
Flooring type product product brochures installation guidelines maintenance guidelines warranty material safety data sheet.
The initial material and installation costs are only part of the total cost of owning a static control floor.
Freestyle esd plus designer.
Ansi esd s20 20 requires that all conductors in an esd protected area including personnel must be grounded.
Or mount a grounding.
Affix the grounding strap to the tile as described in paragraph one.